SMD References PDF Print E-mail

  

BIOGAS PLANT BERLIN:

Specification: 

Pre dump: Monolithic reinforced concrete tank

Volume = 450 m³

Digester: Self Mixing Digester (SMD), no mixer inside

Monolithic reinforced concrete tank with wall and floor heating

Volume = 2.400 m³                       

Follow up fermenter: Monolithic reinforced concrete tank

Volume = 2.500 m³

Desulfurization: external biological desulfurization

CHP-Unit:  537 kW elect.

Input Substrates: cow and pig manure, energy crops

Start-up: 2006

Biogas plant Spreewald

Image 

 

Specification:

Pre dump: Monolithic reinforced concrete tank

 

Volume = 300 m³

 

Digester: Self Mixing Digester (SMD), no mixer inside

 Monolithic reinforced concrete tank with wall and floor heating

Volume = 1.800 m³                  

Follow up fermenter: Monolithic reinforced concrete tank

Volume = 2.500 m³

 

Integrated Desulfurization

 

CHP-Unit: 469 kW elect. 539 kW thermal.

 

Input Substrates: Liquid cow manure, energy crops

 

 

 

Start-up: 2003

 

Biogas plant Magdeburg

Image

 

Specification: 

Pre dump: Monolithic reinforced concrete tank

 

Volume = 300 m³

 

Digester: Self Mixing Digester (SMD), no mixer inside

 

Monolithic reinforced concrete tank with wall and floor heating

 Volume = 1.800 m³ 

Follow up fermenter: Monolithic reinforced concrete tank

Volume = 2.500 m³

 Integrated Desulfurization

Paddle Mixer

CHP-Unit: 537 kW elect. 617 kW therm.  

 

Input Substrates: Liquid manure, maize silage, grain

 

 

 

 

Start up: 2005

 

Biogas plant Neubrandenburg 

Image 

Specification: 

Pre dump: Monolithic reinforced concrete tank

 

Volume = 300 m³

 

Digester: Self Mixing Digester (SMD), no mixer inside

 

 

Monolithic reinforced concrete tank with wall and floor heating

Automatic ground sludge drain to take grit off the digester

 

 

 

Volume = 2.400 m3

 

 

Desulfurization and gas storage:

External biological desulfurization

 

External Gas storage 1.000 m³

 

CHP-Unit:  716 kW elect

 

Production:  about 16.000 kWh elec./d

 

Self energy consumption:  < 5%

 

Heat recover: Heating installation for baby / young pigs

 

Input Substrates: Liquid swine manure, energy crops, 8 to/d poultry manure with >50% DM

Start-up: 2007

 

 

Biogas plant Leipzig

Image 

Specification: 

Pre dump: Monolithic reinforced concrete tank

 

Volume = 400 m³

 

Digester: Self Mixing Digester (SMD), no mixer inside

 

Monolithic reinforced concrete tank with wall and floor heating

 Volume = 2.400 m³ 

Follow up fermenter:Monolithic reinforced concrete tank

Volume = 2.500 m³

 

Integrated Desulfurization

Paddle Mixer

 

CHP-Unit: 537 kW elect. 617 kW thermal.

 

Input Substrates: Liquid cow manure, energy crops

 

Start-up: 2007

 

 

 

 

 

 
Impressum  © 2010 Agroenergien